9 resultados para ELISA Kits

em Instituto Politécnico do Porto, Portugal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Celiac disease is a gluten-induced autoimmune enteropathy characterized by the presence of tissue tranglutaminase (tTG) autoantibodies. A disposable electrochemical immunosensor (EI) for the detection of IgA and IgG type anti-tTG autoantibodies in real patient’s samples is presented. Screen-printed carbon electrodes (SPCE) nanostructurized with carbon nanotubes and gold nanoparticles were used as the transducer surface. This transducer exhibits the excellent characteristics of carbon–metal nanoparticle hybrid conjugation and led to the amplification of the immunological interaction. The immunosensing strategy consisted of the immobilization of tTG on the nanostructured electrode surface followed by the electrochemical detection of the autoantibodies present in the samples using an alkaline phosphatase (AP) labelled anti-human IgA or IgG antibody. The analytical signal was based on the anodic redissolution of enzymatically generated silver by cyclic voltammetry. The results obtained were corroborated with a commercial ELISA kit indicating that the electrochemical immunosensor is a trustful analytical screening tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação foi realizada em colaboração com o grupo empresarial Monteiro, Ribas, tendo como principal objectivo a realização de uma auditoria à gestão dos resíduos industriais produzidos pelas suas fábricas localizadas na Estrada da Circunvalação, no Porto. Para cumprir este objectivo, inicialmente foi efectuado um levantamento das obrigações legais relativas aos resíduos e foram procuradas práticas aconselhadas para a gestão interna. Para cada uma das fábricas, verificaram-se, quais os resíduos produzidos e analisaram-se os seus percursos, considerando as suas origens, os locais e modos de acondicionamento na origem, os modos de transporte interno, os locais e modos de armazenagem preliminar, e ainda, as quantidades produzidas, os transportadores, os operadores finais e as operações finais de gestão, sendo que estas quatro últimas informações são relativas ao ano 2013. De seguida procedeu-se à realização da auditoria nas diferentes unidades, verificando o cumprimento dos requisitos legais e das boas práticas em matéria de gestão de resíduos. As principais não conformidades detectadas, comuns às várias unidades fabris foram a inexistência de local/recipiente definido para acondicionamento de alguns resíduos, a falta ou insuficiente identificação de recipientes/zonas de acondicionamento, a inexistência de bacias de retenção para resíduos líquidos perigosos, o facto de no transporte interno apenas os resíduos perigosos serem cobertos e, os resíduos líquidos perigosos não serem transportados sobre bacias de retenção móveis nem com o material necessário para absorver derrames. Para cada resíduo e para cada unidade industrial foram propostas medidas correctivas e/ou de melhoria, quando aplicável. Relativamente à armazenagem preliminar, a principal inconformidade detectada foi o facto de todos os parques (quatro) possuírem resíduos perigosos no momento das auditorias, o que não é adequado. Foram propostas medidas correctivas e/ou de melhoria para cada parque. Como proposta global, tendo em conta factores económicos e de segurança, sugeriu-se que apenas o parque de resíduos perigosos possa armazenar este tipo de resíduos, pelo que os procedimentos de transporte interno devem ser melhorados, fazendo com que estes resíduos sejam transportados directamente para o parque de resíduos perigosos. Desta forma dois dos parques devem sofrer algumas remodelações, nomeadamente serem cobertos e fechados, ainda que não totalmente, e o parque de resíduos perigosos deve ser fechado, mantendo aberturas para ventilação, deve ser equipado com kit´s de contenção de derrames, fichas de segurança, procedimentos a realizar em caso de emergência, e ainda, devido ao facto do sistema de contenção de derrames ser pequeno face ao total de armazenamento, aconselha-se o uso de bacias de retenção para alguns dos recipientes de resíduos líquidos perigosos. Ao longo deste processo e em consequência da realização da auditoria, algumas situações consideradas não conformes foram sendo corrigidas. Também foram preparadas instruções de trabalho adequadas que serão posteriormente disponibilizadas. Foi ainda elaborada uma metodologia de avaliação de processos como base de trabalho para redução dos resíduos gerados. A etapa escolhida para a aplicação da mesma foi uma etapa auxiliar do processo produtivo da Monteiro, Ribas - Revestimentos, S.A - a limpeza de cubas com solventes, por forma a tentar minimizar os resíduos de solventes produzidos nesta operação. Uma vez que a fábrica já realiza a operação tendo em consideração medidas de prevenção e reutilização, a reciclagem é neste momento a única forma de tentar minimizar os resíduos de solventes. Foram então estudadas duas opções, nomeadamente a aquisição de um equipamento de regeneração de solventes e a contratação de uma operadora que proceda à regeneração dos resíduos de solventes e faça o retorno do solvente regenerado. A primeira opção poderá permitir uma redução de cerca de 95% na produção de resíduos de solventes e na aquisição de solvente puro, estimando-se uma poupança anual de cerca de **** €, com um período de recuperação do capital de cerca de 16 meses e a segunda pode conduzir a uma redução significativa na aquisição de solvente puro, cerca de 65%, e a uma poupança anual de cerca de **** €.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A diabetes mellitus do tipo 1 (DM1) é o distúrbio endócrino-metabólico mais frequente em crianças. É uma doença autoimune resultado da destruição selectiva das células beta pancreáticas. A velocidade de destruição das células beta pode ser rápida em algumas pessoas e lenta em outras; esta última é típica de adulto é conhecido como diabetes autoimune latente em adulto (LADA). A sua etiologia envolve factores ambientais e genéticos, dos genes envolvidos a maior contribuição vem da região do genoma onde estão localizados os genes do Complexo Principal de Histocompatibilidade (MHC). A combinação de diferentes alelos do sistema de antigénio leucocitário humano tipo II (HLAII) esta associada a susceptibilidade da doença e as principais molécula envolvidas são a DQ e DR. O estágio pré-clínico da doença se caracteriza pela presença de auto-anticorpos, sendo o anti-GAD o mais sensível nesta patologia. OBJECTIVO: Analizar a frequência dos polimorfismos HLA-DR/DQ em angolanos portadores de diabetes tipo 1, residentes em Luanda. O tipo de estudo adotado foi casocontrolo num universo de voluntários provenientes da consulta externa de hospitais e clínicas locais no período de outubro de 2012 a outubro 2013. A amostra biológica utilizada foi sangue total, tendo sido processada no laboratório LABGENE, da Faculdade de Medicina (FM) da Universidade Agostinho Neto (UNA). Os auto-anticorpos, anti-GAD, foram doseados pelo método de ELISA. O ADN genómico foi extraído à partir de sangue total periférico e tipagem genética foi realizada mediante PCR-SSP.O alelo DQB1*02 (DQ2/DQ2) (p=0,033, OR= 4, IC (1,2-13,3) foi associado a susceptibilidade da DM1; os alelos DQB1*06 (DQ6/DQ6) (p=0,000, OR=0,30, IC (0,17-0,54); *11 (p=0,011, OR=0,14, IC=0,032-0,62); *13 (p=0,006, OR=0,13, IC=0,049-0,588) e *15 (p=0,001, OR=0,044, IC=0,005-0,39) foram associados a proteção. Foi encontrado 29,2% de positividade para o anti-GAD, não houve associação significativa (p=0,69) entre a resposta positiva do anti-GAD e a idade. Não foi encontrada associação significativa (p=0,39) entre o tempo de diagnóstico e resposta humoral. Observou-se associação significativa entre os alelos de risco DQB1*02 (p=0.000) e resposta positiva para anti-GAD; da mesma maneira houve uma associação significativa para os alelos DQB1*06 (p=0,002), DRB1*11 (p=0,048); *13 (p=0,004) e *15 (p=0,021) e a resposta negativa do anti-GAD.Os dados demostram o forte envolvimentos do gene HLA-II (DQ) com a suceptibilidade a DM1 e sugere que a autoimunidade se desenvolve na presença de susceptibilidade genética, quer dizer, em associação com alelos HLA-II específicos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The restructuring of electricity markets, conducted to increase the competition in this sector, and decrease the electricity prices, brought with it an enormous increase in the complexity of the considered mechanisms. The electricity market became a complex and unpredictable environment, involving a large number of different entities, playing in a dynamic scene to obtain the best advantages and profits. Software tools became, therefore, essential to provide simulation and decision support capabilities, in order to potentiate the involved players’ actions. This paper presents the development of a metalearner, applied to the decision support of electricity markets’ negotiation entities. The proposed metalearner executes a dynamic artificial neural network to create its own output, taking advantage on several learning algorithms implemented in ALBidS, an adaptive learning system that provides decision support to electricity markets’ players. The proposed metalearner considers different weights for each strategy, depending on its individual quality of performance. The results of the proposed method are studied and analyzed in scenarios based on real electricity markets’ data, using MASCEM - a multi-agent electricity market simulator that simulates market players’ operation in the market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports the design of a new remotely operated underwater vehicle (ROV), which has been developed at the Underwater Systems and Technology Laboratory (USTL) - University of Porto. This design is contextualized on the KOS project (Kits for underwater operations). The main issues addressed here concern directional drag minimization, symmetry, optimized thruster positioning, stability and layout of ROV components. This design is aimed at optimizing ROV performance for a set of different operational scenarios. This is achieved through modular configurations which are optimized for each different scenario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação foi realizada em colaboração com o grupo empresarial Monteiro, Ribas e teve como principais objetivos efetuar uma avaliação das melhores técnicas disponíveis relativas à refrigeração industrial e às emissões resultantes da armazenagem. O primeiro objetivo teve como alvo todas as instalações da Monteiro, Ribas enquanto que o segundo objetivo se debruçou sobre Monteiro, Ribas, Embalagens Flexíveis, S.A.. Para cumprir estes objetivos, inicialmente efetuou-se um levantamento das melhores técnicas disponíveis apresentadas nos respetivos documentos de referência. Em seguida selecionaram-se as técnicas que se adequavam às condições e às instalações em estudo e procedeu-se a uma avaliação de forma a verificar o grau de implementação das medidas sugeridas no BREF (Best Available Techniques Reference Document). Relativamente aos sistemas de refrigeração industrial verificou-se que estão implementadas quase todas as medidas referenciadas no respetivo documento de referência. Isto prende-se com o facto dos sistemas de refrigeração existentes no complexo industrial Monteiro, Ribas serem relativamente recentes. Foram implementados no ano de 2012, e são caracterizados por apresentarem uma conceção moderna com elevada eficiência. No que diz respeito à armazenagem de produtos químicos perigosos, a instalação em estudo, apresenta algumas inconformidades, uma vez que a maioria das técnicas mencionadas no BREF não se encontram implementadas, pelo que foi necessário efetuar uma avaliação de riscos ambientais, com recurso à metodologia proposta pela Norma Espanhola UNE 150008:2008 – Análise e Avaliação do Risco Ambiental. Para isso procedeu-se então à formulação de vários cenários de riscos e à quantificação de riscos para à Monteiro, Ribas Embalagens Flexíveis S.A., tendo-se apurado que os riscos estavam avaliados como moderados a altos. Por fim foram sugeridas algumas medidas de prevenção e de minimização do risco que a instalação deve aplicar, como por exemplo, o parque de resíduos perigosos deve ser equipado com kits de contenção de derrames (material absorvente), procedimentos a realizar em caso de emergência, fichas de dados de segurança e o extintor deve ser colocado num local de fácil visualização. No transporte de resíduos perigosos, para o respetivo parque, é aconselhável utilizar bacias de contenção de derrames portáteis e kits de contenção de derrames. Relativamente ao armazém de produtos químicos perigosos é recomendado que se proceda a sua reformulação tendo em conta as MTD apresentadas no subcapítulo 5.2.3 desta dissertação.